Cell Properties (Material/Type) |
Monocrystalline/N-type |
Cell Maker |
LG |
Cell Configuration |
144 Cells (6 x 24) |
Number of Busbars |
9EA |
Module Dimensions (L x W x H) |
2,130mm x 1,042mm x 40mm |
Weight |
22kg |
Glass (Thickness/Material) |
2.8mm/Tempered Glass with AR Coating |
Backsheet (Color) |
Transparent |
Frame (Material) |
Anodized Aluminium |
Junction Box (Protection Degree) |
IP68 with 3 Bypass Diodes |
Cables (Length) |
1,400mm x 2EA |
Connector (Type/Maker) |
MC 4/MC |
Certifications |
IEC 61215-1/-1-1/2:2016, IEC 61730-1/2:2016, UL 61730, ISO 9001, ISO 14001, ISO 50001, OHSAS 18001 |
Salt Mist Corrosion Test |
IEC 61701:2012 Severity 6 |
Ammonia Corrosion Test |
IEC 62716:2013 |
Module Fire Performance |
Type 1 |
Fire Rating |
Class C (UL 790, ULC/ORD C 1703) |
Solar Module Product Warranty |
25 Years |
Solar Module Output Warranty |
Linear Warranty* |
* |
Initial 107%, 1st year 105.4%, After 1st year : -0.35%/year, 96.4% at year 25 (Based on BiFi100) |
NMOT* [°C] |
42 3 |
Pmax [%/°C] |
-0.33 |
Voc [%/°C] |
-0.26 |
Isc [%/°C] |
0.04 |
* |
NMOT (Nominal Module Operating Temperature): Irradiance 800 W/m2, Ambient temperature 20 °C, Wind speed 1 m/s, Spectrum AM 1.5 |
Model |
TBD |
Maximum Power (Pmax) [W] - STC |
327 |
Maximum Power (Pmax) [W] - BiFi100 |
349 |
Maximum Power (Pmax) [W] - BiFi200 |
372 |
MPP Voltage (Vmpp) [V] - STC |
38.2 |
MPP Voltage (Vmpp) [V] - BiFi100 |
38.2 |
MPP Voltage (Vmpp) [V] - BiFi200 |
38.2 |
MPP Current (Impp) [A] - STC |
8.55 |
MPP Current (Impp) [A] - BiFi100 |
9.14 |
MPP Current (Impp) [A] - BiFi200 |
9.73 |
Open Circuit Voltage (Voc) [V] - STC |
45.9 |
Open Circuit Voltage (Voc) [V] - BiFi100 |
45.9 |
Open Circuit Voltage (Voc) [V] - BiFi200 |
45.9 |
Short Circuit Current (Isc) [A] - STC |
8.98 |
Short Circuit Current (Isc) [A] - BiFi100 |
9.60 |
Short Circuit Current (Isc) [A] - BiFi200 |
10.22 |
Model |
TBD |
Maximum Power (Pmax) [W] - STC* |
435 |
Maximum Power (Pmax) [W] - BiFi100** |
465 |
Maximum Power (Pmax) [W] - BiFi200** |
495 |
MPP Voltage (Vmpp) [V] - STC* |
40.7 |
MPP Voltage (Vmpp) [V] - BiFi100** |
40.7 |
MPP Voltage (Vmpp) [V] - BiFi200** |
40.7 |
MPP Current (Impp) [A] - STC* |
10.70 |
MPP Current (Impp) [A] - BiFi100** |
11.44 |
MPP Current (Impp) [A] - BiFi200** |
12.17 |
Open Circuit Voltage (Voc) [V] - STC* |
48.7 |
Open Circuit Voltage (Voc) [V] - BiFi100** |
48.7 |
Open Circuit Voltage (Voc) [V] - BiFi200** |
48.7 |
Short Circuit Current (Isc) [A] - STC* |
11.15 |
Short Circuit Current (Isc) [A] - BiFi100** |
11.92 |
Short Circuit Current (Isc) [A] - BiFi200** |
12.68 |
Module Efficiency [%] - STC* |
19.6 |
Module Efficiency [%] - BiFi100** |
21.0 |
Module Efficiency [%] - BiFi200** |
22.3 |
Pmax Bifaciality Coefficient [%] |
75 5 |
Power Tolerance [%] |
0 ~ +3 |
* |
STC (Standard Test Condition): Irradiance 1000W/m2, Cell temperature 25OC, AM 1.5, Measure Tolerance: 3% |
** |
The electrical properties of BiFi100 and BiFi200 measure under the front side irradiance 1000W/m2 + (100W/m2 or 200W/m2) x BiFi. Use 100W/m2 for BiFi100 and 200W/m2 for BiFi200. |
Operating Temperature [°C] |
-40 ~+85 |
Maximum System Voltage [V] |
1,000(IEC)/1500 |
Maximum Series Fuse Rating [A] |
20 |
Mechanical Test Load (Front) [Pa/psf] |
5,400/113 |
Mechanical Test Load (Rear) [Pa/psf] |
3,000/63 |
* |
Test Load = Design load x Safety Factor (1.5) |
Number of Modules per Pallet [EA] |
25 |
Number of Modules per 40ft HQ Container [EA] |
550 |
Number of Modules per 53' HQ Container [EA] |
750 |
Packaging Box Dimensions (L x W x H) [mm] |
2,160 x 1,120 x 1,213 |
Packaging Box Dimensions (L x W x H) [in] |
TBD |
Packaging Box Gross Weight [kg] |
610 |
Packaging Box Gross Weight [lb] |
TBD |