Cells |
60 Cells (6 x 10) |
Cell Vendor |
LG |
Cell Type |
Monocrystalline/N-type |
Cell Dimensions |
161.7 x 161.7 mm/6 inches |
Cell Properties (Material/Type) |
TBD |
Cell Maker |
TBD |
Cell Configuration |
TBD |
Number of Busbars |
12EA |
Module Dimensions (L x W x H) |
TBD |
Dimensions (L x W x H) |
1,740mm x 1,042mm x 40mm |
Weight |
20.2kg |
Glass |
2.8mm/Tempered Glass with High Transmission Anti-Reflective Coating |
Backsheet (Color) |
TBD |
Frame |
Anodized Aluminium |
Junction Box (Protection Degree) |
TBD |
Cables (Length) |
TBD |
Connector (Type/Maker) |
TBD |
Mechanical Test Load* |
5,400Pa (Front)/4,000Pa (Rear) |
Cooling |
Natural Convection - No Fans |
Enclosure Environmental Rating |
Outdoor - NEMA 250 type 6 (Micro Inverter) |
Operating Ambient Temperature |
-40 ~ +65°C (-40 ~+149°F ) |
Storage Temperature |
-40 ~+65°C |
Inverter Model (Grid Support Utility Interactive) |
LM320UE-A2 |
*Mechanical Test Load |
5,400pa/4,000pa based on IEC 61215 - 2:2016 (Test Load = Design Load x Safety Factor (x1.5)) |
Certifications |
ISO 9001, ISO 14001, ISO 50001, OHSAS 18001 UL1741, IEEE1547, UL1741SA (FCC Part 15 Class B) |
Salt Mist Corrosion Test |
TBD |
Ammonia Corrosion Test |
TBD |
Fire Rating |
TBD |
Module Fire Performance |
Type 1 |
Solar Module Product Warranty |
25 Year Limited |
Solar Module Output Warranty |
TBD |
Micro Inverter Warranty |
25 Year Limited |
Output Warranty of Pmax (DC) (Measurement Tolerance 3%) |
Linear Warranty* Please contact customer support for full warranty details. |
* |
Improved: 1st year %, from 2-24th year: %/year down, % at year 25 |
NMOT |
44 C 3 |
Pmax |
-0.35 |
Voc |
-0.26 |
Isc |
0.03 |
*NOCT |
(Nominal Operating Cell Temperature): Irradiance 800W/m , ambient temperature 20°C, wind speed 1m/s |
* |
NMOT (Nominal Module Operating Temperature): Irradiance 800 W/m2, Ambient temperature 20°C, Wind speed 1 m/s, Spectrum AM 1.5 |
Standard |
TBD |
Rated Voltage/Current |
TBD |
Wire Size Range |
TBD |
Cable Length (only cable length) |
TBD |
Protection Degree |
TBD |
Diameter range of cable |
TBD |
Power (Inverter Rated continuous) [W] |
TBD |
Voltage (Rated Output) [V] |
TBD |
Current (Rated Output) [A] |
TBD |
Max. Continuous Output Power (VA) |
320 |
Nominal Voltage / Range (V) |
240/211 ~ 264 ; 208/183 ~ 229 |
Nominal Output Current (A) |
1.33 ; 1.54 |
Cable Length (only cable length) (mm) |
Cable 1 : 1,200 ; Cable 2 : 1,100 |
Number of Maximum AC Modules |
12 ; 10 |
Nominal Frequency / Range (Hz) |
60.0/59.3~60.5 |
Frequency (Extended) Hz |
TBD |
Power Factor / Adjustable |
1/0.8 leading...0.8 lagging |
Max. Branch Circuit Over Current Protection (A) |
20 |
Max Units Per 20A Branch Circuit |
240V: 12, 208V: 10 |
CEC Weighted Efficiency (%) |
97.0 ; 96.5 |
Model |
TBD |
Maximum Power (Pmax) |
TBD |
MPP Voltage (Vmpp) |
TBD |
MPP Current (Impp) |
TBD |
Open Circuit Voltage (Voc) |
TBD |
Short Circuit Current (Isc) |
TBD |
Model |
TBD |
Maximum Power (Pmax)** |
370 |
MPP Voltage(Vmpp) |
TBD |
MPP Current (Impp) |
TBD |
Open Circuit Voltage (Voc, +/-5%) |
TBD |
Short Circuit Current (Isc, +/-5%) |
TBD |
Module Efficiency |
20.4% |
Power Tolerance (%) |
0 ~ +3 |
*STC (Standard Test Condition) |
Irradiance 1000 W/ , Cell temperature 25 , AM 1.5 , Measure tolerance of Pmax : 3% |
**Measurement Tolerance of Pmax: |
3% |
Operating Temperature [°C] |
TBD |
Maximum System Voltage [V] |
TBD |
Maximum Series Fuse Rating [A] |
TBD |
Mechanical Test Load (Front) [Pa/psf] |
TBD |
Mechanical Test Load (Rear) [Pa/psf] |
TBD |
* |
Based on IEC 61215-2 : 2016 (Test Load = Design Load x Safety Factor(1.5)), Mechanical Test Loads 6,000 Pa/5,400 Pa based on IEC 61215 : 2005 |
Number of Modules per Pallet [EA] |
25 |
Number of Modules per 40ft HQ Container [EA] |
650 |
Number of Modules per 53ft Container [EA] |
850 |
Packaging Box Dimensions (L x W x H) [mm] |
1,790 x 1,120 x 1,213 |
Packaging Box Dimensions (L x W x H) [in] |
TBD |
Packaging Box Gross Weight [kg] |
538 |
Packaging Box Gross Weight [lb] |
TBD |