Cell Properties (Material/Type) |
Monocrystalline/N-type |
Cell Maker |
LG |
Cell Configuration |
60 Cells (6 x 10) |
Number of Busbars |
12EA |
Module Dimensions (L x W x H) |
1,686mm x 1,016mm x 40 mm |
Weight |
17.1kg |
Glass (Material) |
Tempered Glass with AR Coating |
Backsheet (Color) |
White |
Frame (Material) |
Anodized Aluminium |
Junction Box (Protection Degree) |
IP 68 with 3 Bypass Diodes |
Cables (Length) |
1,000mm x 2EA |
Connector (Type/Maker) |
MC 4/MC |
Certifications |
IEC 61215-1/-1-1/2:2016, IEC 61730-1/2:2016, UL 1703, ISO 9001, ISO 14001, ISO 50001, OHSAS 18001 |
Salt Mist Corrosion Test |
IEC 61701:2012 Severity 6 |
Ammonia Corrosion Test |
IEC 62716:2013 |
Module Fire Performance |
Type 1 (UL 1703) |
Fire Rating |
Class C (UL 790, ULC/ORD C 1703) |
Solar Module Product Warranty |
25 Years |
Solar Module Output Warranty |
Linear Warranty* |
* |
Improved: 1st year 98%, from 2-24th year: 0.33%/year down, after 25th year: 90.08% |
NMOT* [°C] |
42 3 |
Pmax [%/°C] |
-0.36 |
Voc [%/°C] |
-0.26 |
Isc [%/°C] |
0.03 |
* |
NMOT (Nominal Module Operating Temperature): Irradiance 800 W/m , Ambient temperature 20 °C, Wind speed 1 m/s, Spectrum AM 1.5 |
Model |
LG345N1C-V5 |
Maximum Power (Pmax) [W] |
259 |
MPP Voltage (Vmpp) [V] |
32.8 |
MPP Current (Impp) [A] |
7.89 |
Open Circuit Voltage (Voc) [V] |
38.8 |
Short Circuit Current (Isc) [A] |
8.49 |
Model |
LG345N1C-V5 |
Maximum Power (Pmax) [W] |
345 |
MPP Voltage (Vmpp) [V] |
34.9 |
MPP Current (Impp) [A] |
9.89 |
Open Circuit Voltage (Voc 5%) [V] |
41.2 |
Short Circuit Current (Isc 5%) [A] |
10.57 |
Module Efficiency [%] |
20.1 |
Bifaciality Coefficient of Power [%] |
10 |
Power Tolerance [%] |
0 ~ +3 |
* |
STC (Standard Test Condition): Irradiance 1000 W/m , cell temperature 25 °C, AM 1.5. |
** |
Measurement Tolerance: 3% |
Operating Temperature [°C] |
-40 ~+90 |
Maximum System Voltage [V] |
1,000 |
Maximum Series Fuse Rating [A] |
20 |
Mechanical Test Load (Front) [Pa/psf] |
5,400/113 |
Mechanical Test Load (Rear) [Pa/psf] |
4,000/84 |
* |
Mechanical Test Load 5,400Pa/4,000Pa based on IEC 61215-2 : 2016, Test Load = Design Load x Safety Factor (1.5) |
Number of Modules per Pallet [EA] |
25 |
Number of Modules per 40ft HQ Container [EA] |
650 |
Packaging Box Dimensions (L x W x H) [mm] |
1,750 x 1,120 x 1,221 |
Packaging Box Gross Weight [kg] |
464 |